Publicación

An approach to the measurement of radon permeability and transmission factor using Cr-39 detectors inside a diffusion chambers exposed in a new-build radon chamber

Jhonny Rojas · M.E. López · Bertin Pérez
2022 SSRN Electronic Journal DOI: 10.2139/ssrn.4252598

Resumen

Many CR-39 (poly allyl glycol carbonate) detectors inside two different diffusion chambers were used to study the radon permeability and the radon transmission factor. This factor represents the percentage of radon concentration that truly enters a diffusion chamber, since there is a loss of radon concentration inside the chamber compared to the outside radon concentration, due to the radioactive nature of radon gas. Here, a theoretical discussion is presented, followed by an experimental study that was carried out in a new-build radon chamber. These initial results are presented in order to check the reliability of the radon chamber. The most remarkable observation is that research consistently shows that the obtained value of radon permeability constant for a commercial membrane is 4.404×10 − 8±0.012×10 − 8cm2/s, which is in a good agreement with literature data.

Autores y colaboradores

Authors

Palabras clave

Radon Detector Transmission (telecommunications) Permeability (electromagnetism)