Nonlinearity Parameter Estimation Method in Pulse-Echo Using a Reference Phantom

Andres Coila, Michael L. Oelze

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

1 Cita (Scopus)

Resumen

The nonlinearity parameter (B/A) of a fluid-like media could be useful to assess structural changes, e.g., for tissue identification. To estimate the B/A, the 2nd harmonic generated signal recorded using a dual transducer could be used. However, in many instances, only the fundamental band signal acquired, for example with a clinical linear array transducer, might be available. In our approach the 2nd harmonic is related to the depletion in the fundamental band signal when comparing echo signal envelopes collected using two different excitation pressures: low and high. Specifically, we use the energy conservation principle by relating the 2nd harmonic to the loss of power at the fundamental band as it propagates in lossy media. Our method assumes that for propagation in a lossy medium, energy from the fundamental band is transferred mainly to the 2nd harmonic, and that propagation at low power settings are quasi-linear. Data were taken from numerical phantoms by simulating a typical linear array and 3D random density media excited with a broadband 5-MHz Gaussian pulse at two excitation peak pressures, i.e., low and high of 100 kPa and 1 MPa, respectively. A well-characterized reference phantom with similar speed of sound and attenuation coefficient as the sample and known B/A was used for calibration of the unknown scattering properties of the assessed sample. An expression for estimation of the B/A of a nonuniform medium is presented. The interrogated media for testing was simulated as a nonuniform phantom with a background B/A=6 and an 18-mm diameter circular inclusion (B/A=9). The result obtained was a parametric image of the B/A versus depth that captures nonlinear changes at the location of the inclusion and below it. The results reflect the cumulative nature of the nonlinearity parameter due to the shadowing effect observed below the location of the inclusion. In summary, the method is able to derive a quantitative B/A map using a reference phantom, with potential to characterize nonlinear media with a simple pulse-echo acquisition setup.

Idioma originalInglés
Título de la publicación alojadaLAUS 2021 - 2021 IEEE UFFC Latin America Ultrasonics Symposium, Proceedings
EditorialInstitute of Electrical and Electronics Engineers Inc.
ISBN (versión digital)9781665443593
DOI
EstadoPublicada - 2021
Publicado de forma externa
Evento2021 IEEE UFFC Latin America Ultrasonics Symposium, LAUS 2021 - Gainesville, Estados Unidos
Duración: 4 oct. 20215 oct. 2021

Serie de la publicación

NombreLAUS 2021 - 2021 IEEE UFFC Latin America Ultrasonics Symposium, Proceedings

Conferencia

Conferencia2021 IEEE UFFC Latin America Ultrasonics Symposium, LAUS 2021
País/TerritorioEstados Unidos
CiudadGainesville
Período4/10/215/10/21

Huella

Profundice en los temas de investigación de 'Nonlinearity Parameter Estimation Method in Pulse-Echo Using a Reference Phantom'. En conjunto forman una huella única.

Citar esto