Implementation of scatterer size imaging on an ultrasonic breast tomography scanner

Roberto J. Lavarello, Michael L. Oelze, Michael Berggren, Steven Johnson, Marko Orescanin, Rebecca Yapp

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

9 Citas (Scopus)

Resumen

Quantitative ultrasound (QUS) techniques make use of frequency-dependent information from backscattered echoes normally discarded in conventional B-mode imaging. Using scattering models and spectral fit methods, properties of tissue microstructure can be estimated. The use of full angular spatial compounding has been proposed as a means of improving the variance of scatterer property estimates and spatial resolution of QUS imaging. In this work, preliminary experimental results from a QUS implementation on an ultrasonic breast tomography scanner from TechniScan, Inc. are presented. The imaging target consisted of a cylindrical gelatin phantom of 7.8 cm diameter. The phantom contained uniformly distributed glass bead inclusions of 85 m mean diameter. The scanner provided reflection-mode data using arrays with 6 MHz nominal center frequency for 17 different angles of view distributed between 0° and 360°. Tomographic images of speed of sound were also generated by the scanner and used for refraction-compensation and registration of the effective scatterer diameter (ESD) estimates corresponding to ROIs at different angles of view. Only data from the surface of the array to the center of the tomography gantry were analyzed for each angle of view, which resulted in 8.5 effective angles of view per ROI. ESD estimates were obtained using ROIs of size 4 mm by 4 mm with a 50% overlap. The average mean and standard deviation of the single angle of view estimates considering the 17 data sets were 85.4 μm and 12.2 μm, respectively. The resulting ESD mean and standard deviation of the compounded image were 85.2 μm and 4.1 μm, respectively. The preliminary experimental results presented here represent the first implementation of QUS on an ultrasonic breast tomography scanner and demonstrate some of the benefits of integrating these technologies, i.e., the availability of full angular spatial compounding and integration with tomographic speed of sound images.

Idioma originalInglés
Título de la publicación alojada2009 IEEE International Ultrasonics Symposium and Short Courses, IUS 2009
EditorialInstitute of Electrical and Electronics Engineers Inc.
Páginas305-308
Número de páginas4
ISBN (versión impresa)9781424443895
DOI
EstadoPublicada - 2009
Publicado de forma externa
Evento2009 IEEE International Ultrasonics Symposium, IUS 2009 - Rome, Italia
Duración: 20 set. 200923 set. 2009

Serie de la publicación

NombreProceedings - IEEE Ultrasonics Symposium
ISSN (versión impresa)1051-0117

Conferencia

Conferencia2009 IEEE International Ultrasonics Symposium, IUS 2009
País/TerritorioItalia
CiudadRome
Período20/09/0923/09/09

Huella

Profundice en los temas de investigación de 'Implementation of scatterer size imaging on an ultrasonic breast tomography scanner'. En conjunto forman una huella única.

Citar esto