Determinación de las causas de los daños por corrosión presentados en un tanque de almacenamiento de acero inoxidable

C. Víctor Andrade, S. Halter García, M. Santiago Flores

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

Resumen

This article presents the results of the assessment of corrosion damage occurred in a storage tank made of stainless steel, in order to determine its probable origin. Before the tank was put in service (storage of sulfonic acid solution), corrosion damage of stainless steel sheets and welded joints were observed after an hydrostatic test. The water used for the hydrostatic test was kept inside the tank for about 7 weeks after the test was performed. In the meantime, a corrosion process took place, which was accelerated by water aggressiveness and by a bad internal finishing of sheets and welded joints. On site evaluation was followed by laboratory tests.

Título traducido de la contribuciónCorrosion failure analysis of a stainless steel storage tank
Idioma originalEspañol
Páginas (desde-hasta)29-34
Número de páginas6
PublicaciónRevista Latinoamericana de Metalurgia y Materiales
N.ºSUPPL.4
EstadoPublicada - 2012

Palabras clave

  • Chloride ions
  • Corrosion
  • Localized corrosion
  • Microstructure
  • Pitting
  • Stainless steels
  • Storage tank
  • Welding
  • Well water

Huella

Profundice en los temas de investigación de 'Determinación de las causas de los daños por corrosión presentados en un tanque de almacenamiento de acero inoxidable'. En conjunto forman una huella única.