TY - GEN
T1 - Ultrasonic attenuation imaging in a rodent thyroid cancer model
AU - Zenteno, Omar
AU - Ridgway, William
AU - Sarwate, Sandhya
AU - Oelze, Michael
AU - Lavarello, Roberto
PY - 2013
Y1 - 2013
N2 - The incidence of diagnosed thyroid cancer has increased significantly over the last decades. Although advances in ultrasonic imaging have increased the malignancy detection rate, current ultrasonic imaging markers do not provide a sufficient level of diagnostic accuracy to replace biopsy. Recent studies suggest that ultrasound parameters derived from backscatter coefficients may allow differentiating among different types of thyroid tumors and normal tissues in a rodent model ex vivo. In this work, the potential use of attenuation coefficient (AC) estimates for the same purpose was explored. A sample set of 24 excised mice thyroids were scanned using a 40-MHz, f/3 single element transducer. The experimental dataset contained six animals that developed papillary thyroid carcinoma (PTC), five that developed follicular variant papillary thyroid carcinoma (FV-PTC), five that developed c-Cell adenoma (c-Cell) and eight that did not develop thyroid abnormalities (control). AC slope maps were generated with a spectral log difference method using 0.5mm by 0.5mm data blocks. Outliers of each slice due to artifacts in AC estimation were discarded using the Thompson Tau method. Finally, a Kruskal-Wallis test was conducted to analyze if statistically significant differences in the mean AC slope among the four groups existed. The median and interquartile range for each group were 1.29 and 0.22 dB/cm-MHz for the control group, 1.64 and 0.09 dB/cm-MHz for c-Cell, 1.16 and 0.12 dB/cm-MHz for PTC and 1.33 and 0.08 dB/cm-MHz for FV-PTC, respectively. These values are consistent with previous reports of attenuation in thyroid tissues. The Kruskal-Wallis test reported statistically significant differences between the c-Cell group and the other groups of study and between the PTC and FV-PTC groups (p<0.05). These preliminary results suggest that the AC may be used to characterize thyroid tissues.
AB - The incidence of diagnosed thyroid cancer has increased significantly over the last decades. Although advances in ultrasonic imaging have increased the malignancy detection rate, current ultrasonic imaging markers do not provide a sufficient level of diagnostic accuracy to replace biopsy. Recent studies suggest that ultrasound parameters derived from backscatter coefficients may allow differentiating among different types of thyroid tumors and normal tissues in a rodent model ex vivo. In this work, the potential use of attenuation coefficient (AC) estimates for the same purpose was explored. A sample set of 24 excised mice thyroids were scanned using a 40-MHz, f/3 single element transducer. The experimental dataset contained six animals that developed papillary thyroid carcinoma (PTC), five that developed follicular variant papillary thyroid carcinoma (FV-PTC), five that developed c-Cell adenoma (c-Cell) and eight that did not develop thyroid abnormalities (control). AC slope maps were generated with a spectral log difference method using 0.5mm by 0.5mm data blocks. Outliers of each slice due to artifacts in AC estimation were discarded using the Thompson Tau method. Finally, a Kruskal-Wallis test was conducted to analyze if statistically significant differences in the mean AC slope among the four groups existed. The median and interquartile range for each group were 1.29 and 0.22 dB/cm-MHz for the control group, 1.64 and 0.09 dB/cm-MHz for c-Cell, 1.16 and 0.12 dB/cm-MHz for PTC and 1.33 and 0.08 dB/cm-MHz for FV-PTC, respectively. These values are consistent with previous reports of attenuation in thyroid tissues. The Kruskal-Wallis test reported statistically significant differences between the c-Cell group and the other groups of study and between the PTC and FV-PTC groups (p<0.05). These preliminary results suggest that the AC may be used to characterize thyroid tissues.
KW - Attenuation imaging
KW - Thyroid cancer
KW - Tissue characterization
UR - http://www.scopus.com/inward/record.url?scp=84894361785&partnerID=8YFLogxK
U2 - 10.1109/ULTSYM.2013.0023
DO - 10.1109/ULTSYM.2013.0023
M3 - Conference contribution
AN - SCOPUS:84894361785
SN - 9781467356862
T3 - IEEE International Ultrasonics Symposium, IUS
SP - 88
EP - 91
BT - 2013 IEEE International Ultrasonics Symposium, IUS 2013
T2 - 2013 IEEE International Ultrasonics Symposium, IUS 2013
Y2 - 21 July 2013 through 25 July 2013
ER -