Skin closure with 2-octyl cyanoacrylate and polyester mesh after primary total knee arthroplasty offers superior cosmetic outcomes and patient satisfaction compared to staples: a prospective trial

Kavin Sundaram, Nicolas S. Piuzzi, Brendan M. Patterson, Kim L. Stearns, Viktor E. Krebs, Michael A. Mont

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

Introduction: The goals of this study were to compare patient satisfaction and wound-related complications in patients receiving 2-octyl cyanoacrylate (glue) and polyester mesh for skin closure after primary total knee arthroplasty (TKA) versus staples. Methods: A total of 60 knees in 54 patients undergoing TKA were enrolled in a prospective trial and randomized to receive either skin closure with glue and polyester mesh (n = 30) or a control group closed with staples (n = 30). Hollander wound cosmesis score (measured on a scale of 0–5, with 0 being the best) and visual analog scale (VAS) scores (range 0–100 mm) for patient satisfaction with wound cosmesis, as well as wound-related readmission, reoperation, and complications, including superficial surgical site infection, wound dehiscence, wound hematoma, stitch abscess, and wound discharge, were assessed at 6 weeks and 90 days after TKA. Baseline characteristics were not statistically significantly different between the groups (p > 0.05). Results: At 6 weeks and 90 days, the Hollander wound cosmesis score was significantly lower (p < 0.01) in the glue and polyester mesh groups. Similarly, at 6 weeks and 90 days, the VAS for patient satisfaction with wound cosmesis was significantly higher (p < 0.01) in the glue and polyester mesh groups. The rate of superficial surgical site infection was 1/30 (3%) in glue and polyester mesh groups versus zero in the control group (p = 1.00). The rate of wound dehiscence was 1/30 (3%) in glue and polyester mesh groups versus zero in the control group (p = 1.00). Conclusion: These results suggest that glue and polyester mesh closure may offer superior cosmetic outcomes to staples for skin closure in TKA.

Original languageEnglish
Pages (from-to)447-453
Number of pages7
JournalEuropean Journal of Orthopaedic Surgery and Traumatology
Volume30
Issue number3
DOIs
StatePublished - 1 Apr 2020
Externally publishedYes

Keywords

  • 2-octyl cyanoacrylate
  • Staples
  • Total knee arthroplasty
  • Total knee replacement
  • Wound closure
  • Wound complications
  • Wound cosmesis

Fingerprint

Dive into the research topics of 'Skin closure with 2-octyl cyanoacrylate and polyester mesh after primary total knee arthroplasty offers superior cosmetic outcomes and patient satisfaction compared to staples: a prospective trial'. Together they form a unique fingerprint.

Cite this