TY - GEN
T1 - A quasi-local method for instantaneous frequency estimation with application to structural magnetic resonance images
AU - Ulloa, Alvaro
AU - Rodriguez, Paul
AU - Liu, Jingyu
AU - Calhoun, Vince
AU - Pattichis, Marios
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/11/2
Y1 - 2014/11/2
N2 - Spatially-varying signal content can be effectively modeled using amplitude modulation-frequency modulation (AM-FM) representations. The AM-FM representation allow us to extract instantaneous amplitude (IA) and instantaneous frequency (IF) components that can be used to measure non-stationary content in biomedical images and videos. This paper introduces a new method for estimating the IA and the IF based on a quasi-local method (QLM). We provide an extensive comparison of AM-FM demodulation approaches based on QLM and a quasi-eigenfunction approximation method using three different filter-banks: (i) a separable, equiripple design, (ii) a Gabor filter bank, and (iii) a directional filter bank approach based on the Contourlet transform. The results document that the use of the new QLM method with an equiripple filter bank design gave the best IF magnitude estimates for a synthetic image. The new QLM method is then applied to a multi-site schizophrenia dataset (N=307). The dataset included structure magnetic resonance images from healthy controls and patients diagnosed with schizophrenia. The IF magnitude is shown to be less sensitive to variations across sites as opposed to the standard use of SMRI images that suffered from significant dependency on the scanner configurations on different collection sites. Furthermore, the regions of interest identified through the use of the IF magnitude are in agreement with previous studies.
AB - Spatially-varying signal content can be effectively modeled using amplitude modulation-frequency modulation (AM-FM) representations. The AM-FM representation allow us to extract instantaneous amplitude (IA) and instantaneous frequency (IF) components that can be used to measure non-stationary content in biomedical images and videos. This paper introduces a new method for estimating the IA and the IF based on a quasi-local method (QLM). We provide an extensive comparison of AM-FM demodulation approaches based on QLM and a quasi-eigenfunction approximation method using three different filter-banks: (i) a separable, equiripple design, (ii) a Gabor filter bank, and (iii) a directional filter bank approach based on the Contourlet transform. The results document that the use of the new QLM method with an equiripple filter bank design gave the best IF magnitude estimates for a synthetic image. The new QLM method is then applied to a multi-site schizophrenia dataset (N=307). The dataset included structure magnetic resonance images from healthy controls and patients diagnosed with schizophrenia. The IF magnitude is shown to be less sensitive to variations across sites as opposed to the standard use of SMRI images that suffered from significant dependency on the scanner configurations on different collection sites. Furthermore, the regions of interest identified through the use of the IF magnitude are in agreement with previous studies.
UR - http://www.scopus.com/inward/record.url?scp=84929485954&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2014.6943880
DO - 10.1109/EMBC.2014.6943880
M3 - Conference contribution
C2 - 25570248
AN - SCOPUS:84929485954
T3 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
SP - 1477
EP - 1480
BT - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
Y2 - 26 August 2014 through 30 August 2014
ER -